Windstorm Products Compliance Information


Please note:  These files are saved in Adobe Acrobat™ 6.0; Click here to download a copy.
Design Pressure Type of Opening Size of Opening Hardware Door Face Type Dade County Acceptance Number Florida Building Commission Approval Number Construction Requirements
+/-100 Door and Frame 3'0"x7'0" Sargent 8200 with deadbolt function 707 Flush N/A FL8394.5 D1, F2
+/-85 Door and Frame 4’0"x7’0" Sargent 8200 with surface bolts 747 Flush N/A N/A D14,F6
+/-85 Door and Frame 3’0"x7’0" Sargent 6500 707 Flush N/A FL8394.4 D1
+/-85 Door and Frame 3’0"x7’0" Sargent 6500 707 Flush N/A FL6705 D1
+/-80 Door and Frame 3’0"x7’0" Sargent 8900 707 Flush N/A FL8394.3 D1, F2
+/-75 Door and Frame 8’0"x8’0" Sargent HC8700 Sargent 8200 with surface bolts on both leafs 747 Flush N/A N/A F1
+/-72 Door and Frame 3’0"x7’0" Sargent 8200/Sargent 10 line 707 Up to HG
(24 x 32)
03-0626.01
N/A
FL2198-R2
FL8394.6
D1, D5
+/-70 Door and Frame 8’0"x8’0" Sargent HC8800 or Sargent MD8600 or Yale 7150 707 or 747 Up to HG
(32 x 42)
03-0812.07
N/A
FL2493-R1
FL8768
D1, D3, D4, D6, D7, D14, D15, F3, F6, F12
+/-70 Door and Frame 8’0"x8’0" Corbin Russwin ML2000, Sargent 8200, Yale 8800 All locks require latch bolt and dead bolt 707, 747 or 727 Up to HG
(32 x 42)
N/A FL8768 D1, D3, D4, D6, D9, D10, D11, F1, F2, F8
+/-70 Door and Frame 3’0"x7’0" Mortise lock with latch bolt and dead bolt; Cylindrical lock and Deadbolt; Interconnected Lock (Contact Factory) 607, 707, 727 or 747 12"x33" N/A
N/A
FL6087
FL8768
D5, D12, F9, F11
+/-62 Door and Frame 8’0"x8’0" Sargent HC8700 747 Flush N/A FL8394.8 D14, F1, F7
+/-60 Store Front Frame: 10'0" height N/A N/A Glasslam Laminated Glass 707 or 747 panels 04-0622.05 FL3704-R1 F4, F5
+/-60 Door and Frame w/wo transom Door: 6’0"x8’0"
Frame: 6'0"x8'0"
Sargent HC8800 or Sargent MD8600 or Corbin Ruswin ML2000 with deadbolt and latch 707 or 747 Up to FG
(24 x 66)
04-0622.06 FL3192-R1 D1, D3, D4, D6, D7, D14, D15, F2, F3, F4, F5, F6, F12
+/-60 Door and Frame 6’0"x7’0" Sargent 8200 with deadbolt and latch bolt 707 F N/A FL8394.1 D1, D2, D8, F1, F8
+/-60 Door and Frame
3’0"x7’0"
Cylindrical Lock Mortise Lock Rim Exit Mortise Exit
(contact factory)
607 707 727 747 Doors May be inswing or out swing F Up to FG
(24 x 66)
N/A FL6351-R1
w/wo transom 3'0"x10'2" D5, F5, F6, F11
w/wo sidelite 4'0"x7'0"
+/-57.2 Door and Frame 4’0" x 7’0" Sargent HC8800 747 F N/A FL8394.7 D14, F6
+/-50 Door and Frame 8’0" x 8’0" Sargent 10 line or 6500 Series with 480 deadbolt 707 FGL up to 32" x 74" 03-0319.04
N/A
FL2198-R2
FL8394.2
D1, D5, D15, F1, F8, F12

D1-Weld Lock and Hinge Channels to Top and Bottom Channels
D2-Non-Standard 12 gauge strike reinforcement for the inactive leaf of pairs of doors with a mortise lock
D3-Requires 12 gauge lock channel
D4-Requires 12 gauge top and bottom channel
D5-Requires 20 gauge channel surround
D6-Requires 14 gauge channel surround for glazed doors
D7-Requires 14 gauge hat shaped horizontal stiffener at device centerline
D8-Requires 12 gauge top cap on inactive leaf
D9-Requires specially constructed active leaf
D10-Requires specially constructed inactive leaf
D11-Requires 14 gauge top cap welded 3" on center on active leaf
D12-Door may be in swing or out swing
D-13 Requires FEMA 320 Door construction
D-14 Requires 20 gauge stiffeners for 747 doors
D-15 Requires 3/8" undercut

F1-Requires 12 gauge full sleeve centered in the head of the frame.
F2-Requires 7 gauge plate reinforcement at the strike on single doors with mortise locks or mortise exits
F3-Requires 12 gauge half sleeve centered in the head of the frame of pairs in addition to the required hardware prep
F4-Requires 10 gauge formed I-beam in mullions that are 3' long or greater
F5-Frames with glass or fixed panels require anchors in the head and/or sill
F6-Frames require 12 gauge full sleeve at strike for single doors with rim exits
F7-Anchors required in head of frame
F8-Anchors required in head of frame for faces greater than 2"
F9-Door may be in swing or out swing
F10-Requires FEMA 320 frame construction
F11-ReadySet Frame Allowed
F12-Requires 10 inch hinge reinforcements
F13-Requires anchors at the still end of hollow metal mullion


ASSA ABLOY